number of labels1
color of the labelA = black
product brand nameSIRIUS ACT
product designationEnclosures
protection class IPIP66, IP67, IP69(IP69K)
— at 50 Hz rated value5 ... 500 V
— at 60 Hz rated value5 ... 500 V
design of the housingwith recess for label
number of LED modules0
material of the holderPlastic
color of the front ringblack
product feature lockoutNo
design of the front ringStandard
number of backing plates0
number of command points1
product type designation3SU1
type of unlocking deviceA = without
material of the enclosureplastic
number of contact modules2
material of the front ringplastic
Substance Prohibitance (Date)10/01/2014
number of inscription plates1
product component front ringYes
shape of the enclosure frontSquare
color of the actuating elementred
shape of the actuating elementround
color of the enclosure top partgrey
design of the actuating elementmushromm pushbutton
degree of protection NEMA rating1, 2, 3, 3R, 4, 4X, 12K, 13
fastening method of the enclosureVertical
material of the actuating elementplastic
shape of the installation openinground
reference code according to IEC 81346-2S
product extension optional light sourceNo
suitability for use EMERGENCY OFF switchNo
design of the interface for communicationwithout
tightening torque with screw-type terminals0.8 ... 0.9 N·m
type of electrical connection on enclosureCable routing above and below, both 1 x M20
design of the contact of auxiliary contactsSilver alloy
fastening method of modules and accessoriesFloor mounting
equipment of commanding and signaling deviceA = mushroom pushbutton
number of NC contacts for auxiliary contacts1
number of NO contacts for auxiliary contacts1
continuous current of the DIAZED fuse link gG10 A
continuous current of the C characteristic MCB10 A; for a short-circuit current smaller than 400 A
tightening torque of the screws in the bracket1 ... 1.2 N·m
continuous current of the quick DIAZED fuse link10 A
type of electrical connection of modules and accessoriesScrew-type terminal
tightening torque of fixing screws in the enclosure cover1.5 ... 1.7 N·m
environmental category during operation according to IEC 607213M6, 3S2, 3B2, 3C3, 3K6 (with relative air humidity of 10 ... 95%, no condensation in operation permitted for all devices behind front panel)