Note:The Tone Mask of the Green Phy defined in DIN 70121 for North America applies
— Number, max.1; 1 per channel
Mounting typestandard rail
Weight, approx.51 g
Current-sinkingYes
Rated value (DC)24 V
Firmware versionV1.0.5
usable BaseUnitsBU type B0, B1
Bus communicationYes; Backplane bus
Mounting positionHorizontal, vertical
to SIMATIC S7-1500Yes
Number of channels1; Acc. to IEC 61851-1 Mode 4 and DIN SPEC 70121
short-circuit proofYes
Degree of pollution2
Product descriptionTechnology module for the conductive charging of electric vehicles according to DIN 70121
HW functional status1
Isolation tested with707 V DC
Type of analog outputControl pilot including Powerline Green Phy, acc. to DIN SPEC 70121
Type of digital outputTransistor
Type of supply voltageDC
Current consumption, max.100 mA
Current consumption, typ.40 mA
IP degree of protectionIP20
Number of analog inputs1; plug present according to IEC 61851
Connection of a DC motorNo
Number of analog outputs1
Number of digital inputs0
Product type designationECC PL ST
Number of digital outputs2; 1x digital out TRIP function as open collector, 1x digital out (DQ P) as open collector
Certificate of suitabilityCE / RCM / EAC / UL / KC
Reverse polarity protectionYes; against destruction
Digital inputs, parameterizableNo
— Cycle duration, parameterizableNo; 1 kHz
Mean time between failures (MTBF)114.14 a; @ 25 °C
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Electrostatic discharge acc. to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-related interference acc. to IEC 61000-4-310 V/m (80 ... 1 000 MHz), 3 V/m (1.4 ... 2.0 GHz), 1 V/m (2.0 ... 2.7 GHz)
Vehicle communication according to IEC 61851Yes; Mode 4
Conducted interference due to burst acc. to IEC 61000-4-42 kV signal lines
Conducted interference due to surge acc. to IEC 61000-4-5On DC supply lines: 0.5 kV symmetrical and asymmetrical
Conducted interference due to high-frequency radiation acc. to IEC 61000-4-610 V (0.15 ... 80 MHz)