CE markYes
UL approvalNo
Overload-proofYes
Rated value (DC)36 V; with MED280: at 24 V DC max. door speed of 500 mm/s, at 28.8 V DC max. door speed of 800 mm/s. With MEG251: at 24 V DC max. door speed of 500 mm/s, at 28.8 V DC max. door speed of 750 mm/s
— at 30 V DC, max.0.5 A
— at 30 V DC, min.0.01 A
Standard for EMCEN 61000-6-2 / EN 61000-6-4 / EN 61326-3-1 / EN 50121-3-2 / EN50121-4 / EN50121-5
Output voltage (DC)24 V; Ensure correct polarity! CAUTION: Do not supply with external voltage!
Active power input80 W
Interfaces/bus typePROFINET according to Conformance Class A, B, C; integrated switch for linear and ring structure
Kinetic energy, max.75 J
short-circuit proofYes
Weight of door, max.280 kg
Degree of pollution2
Standard for safetyEN 61010-1 / EN 61010-2-201 / EN 14752 / EN ISO 13849-1 Cat. 2 PL d / IEC 62061: SIL 2
Overvoltage category2
China RoHS complianceYes
Active power input, max.540 W
Control inputs isolatedYes
IP degree of protectionIP20
Product type designationATE530S COATED
Control inputs p-switchingYes
Opening width of door, max.5 m
Opening width of door, min.0.35 m
Design of the power supplyVia SIDOOR TRANSFORMER or via DC
Optional product expansionStandard mounting rail holder 6FB1144-0AT00-3AS0
Active power input (standby mode)7 W
Mean time between failures (MTBF)13 a
Protection in case of DC supplyUse of a circuit breaker in the supply path according to 60898-1, 8A, C-characteristic type SIEMENS: 5SY4108-7 or 5SY4108-7KK11
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)37.1 V
Operating cycle frequency of door, max.180 1/h
Installation and mounting instructionsNo direct exposure to the sun