JRBSupplier
BerandaProdukMerekTentangKontak

Perusahaan

  • Tentang
  • Kontak

Produk

  • Produk
  • Kategori
  • Merek

Tautan Cepat

  • Beranda
  • Blog

Kontak

  • +6285121062779
  • info@jrbsupplier.com
  • Cilegon, Banten

© 2026 JRB Supplier. Hak cipta dilindungi.

ProdukCircuit breakers and fusesResidual current circuit breaker (RCCB) moduleRC unit for 5SY
Aktif

RC unit for 5SY

Nomor Part: 5SM2322-6

Merek

Siemens
SiemensKunjungi Situs Web

Kategori

Residual current circuit breaker (RCCB) module

Permintaan WhatsApp

Siemens 5SM2322-6. RC unit for 5SY, 2-pole, type A, In: 40 A, 30 mA, Un AC: 230 V.

Spesifikasi

Mechanical

Net Weight188 g

Dimensions

Width36 mm
Height90 mm
Depth70 mm

Other

design of pole2 poles
number of poles2
product versionfor 5SY
fastening methodDIN rail
mounting positionany
installation depth70 mm
product brand nameSENTRON
degree of pollution2
product designationRCD-unit
protection class IPIP20, if the distribution board is installed, with connected conductors
— at 40 °C rated value37.2 A
— at 45 °C rated value37.2 A
— at 50 °C rated value36 A
— at 55 °C rated value34.8 A
— at 60 °C rated value34 A
— at 65 °C rated value33.2 A
— at 70 °C rated value32 A
overvoltage categoryIII
design of the productInstantaneous
residual current typeA
product feature sealableNo
product type designation5SM2
number of modular width units2
position of power supply cordtop or bottom
insulation voltage (Ui) rated value460 V
protection function false trippingYes
tripping fault current rated value30 mA
surge current resistance rated value1 kA
surge voltage resistance rated value4 000 V
reference code according to IEC 81346-2F
value range of the operating frequency50 Hz
product feature OFF-delay time adjustableNo
type of voltage of the operating voltageAC
value range of the supply voltage frequency50 Hz
product feature rated fault current adjustableNo
mechanical service life (operating cycles) typical10 000
size of installation devices according to DIN 438801
touch protection against electrical shock according to EN 50274Finger and back-of-hand safe
number of test cycles for environmental testing according to IEC 60068-2-3028

Unduhan

5SM2322-6_doc_05SM2322-6_doc_15SM2322-6_doc_25SM2322-6_doc_35SM2322-6_doc_45SM2322-6_doc_55SM2322-6_doc_65SM2322-6_datasheet.pdf

Pertanyaan yang Sering Diajukan

Anda Mungkin Juga Suka

RC unit for 5SY by Siemens

Siemens

RC unit for 5SY

5SM2121-6

RC unit for 5SY by Siemens

Siemens

RC unit for 5SY

5SM2322-6KK01

RC unit for 5SY by Siemens

Siemens

RC unit for 5SY

5SM2322-0

RC unit for 5SY by Siemens

Siemens

RC unit for 5SY

5SM2322-3

No image

ABB

DDA202 AC-40/0.03 - Residual current circuit breaker (RCCB) module

2CSB202001R1400

No image

ABB

DDA202 AC-63/0.03 - Residual current circuit breaker (RCCB) module

2CSB202001R1630

No image

ABB

DDA202 AC-25/0.1 - Residual current circuit breaker (RCCB) module

2CSB202001R2250

No image

ABB

DDA202 AC-25/0.03 - Residual current circuit breaker (RCCB) module

2CSB202001R1250

Lainnya dari Siemens

No image

Siemens

WATER TRAP D TO DIN 16282 120 CEL/100 BAR

M56340-A0063

No image

Siemens

PRESSURE IMPACT REDUCER STAINLESS STEEL

M56340-A0059

No image

Siemens

WATER TRAP B TO DIN 16282 120 CEL/100 BAR

M56340-A0061

No image

Siemens

INSTRUMENT BRACKET

M56340-A0046

No image

Siemens

INSTRUMENT BRACKET

M56340-A0053

No image

Siemens

PRESSURE IMPACT REDUCER BRASS

M56340-A0054

No image

Siemens

INSTRUMENT BRACKET

M56340-A0047

No image

Siemens

INSTRUMENT BRACKET

M56340-A0079