JRBSupplier
BerandaProdukMerekTentangKontak

Perusahaan

  • Tentang
  • Kontak

Produk

  • Produk
  • Kategori
  • Merek

Tautan Cepat

  • Beranda
  • Blog

Kontak

  • +6285121062779
  • info@jrbsupplier.com
  • Cilegon, Banten

© 2026 JRB Supplier. Hak cipta dilindungi.

ProdukLow-voltage industrial componentsThree-phase control transformertransformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 2.5 /11; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 3.6-6.26; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1
Aktif

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 2.5 /11; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 3.6-6.26; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

Nomor Part: 4AP2742-8BC40-0HA0

Merek

Siemens
SiemensKunjungi Situs Web

Kategori

Three-phase control transformer

Permintaan WhatsApp

Siemens 4AP2742-8BC40-0HA0. transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 2.5 /11; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 3.6-6.26; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1, -2-2, -2-4 >UL/CSA-recognized< >control transformer< >isolation transformer<.

Spesifikasi

Dimensions

Width0.264 mm
Height0.242 mm
Depth0.242 mm

Other

efficiency0.94
fastening methodscrews
product brand nameSIDAC
product designationtransformer SITAS
protection class IPIP00
short-term vector power11 000
certificate of suitabilityCE / cRUus
phase number of the inputs3
phase number of the outputs3
number of shielding windings0
relative short-circuit voltage3.89
ambient temperature rated value40
connection method for transformersIIIiii0
construction form of the iron core3UI 132/70
operating apparent power rated value2 500
thermal class according to IEC 60085B

Unduhan

4AP2742-8BC40-0HA0_datasheet.pdf

Pertanyaan yang Sering Diajukan

Anda Mungkin Juga Suka

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 1.44-2.50; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 1.44-2.50; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2142-8BC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 1.4-2.5; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 1.4-2.5; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2142-8CC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.0; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.0; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2542-8BC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 0.63 /1.8; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 0.9-1.57; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 0.63 /1.8; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 0.9-1.57; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2042-8BC40-0HA0

No image

Siemens

Thread adapter for use with the Sitrans LCS100 Point Level Switch: Converts G1" (Female) to G1.5" (Male) Thread Standard: DIN ISO 228-1 Material: Stainless Steel 316L (1.4404)

A5E54245949

No image

Siemens

Thread adapter for use with the Sitrans LCS100 Point Level Switch. NPT 3/4" (Female) to 1 1/4" (Male) Thread Standard: ASME B1.20.1 Material: Stainless Steel 316L (1.4404)

A5E54245951

No image

Siemens

Thread adapter for use with the Sitrans LCS100 Point Level Switch. NPT 3/4" (Female) to NPT 1 1/2" (Male) Thread Standard: ASME B1.20.1 Material: Stainless Steel 316L (1.4404)

A5E54245950

continuous light element by Siemens

Siemens

continuous light element

8WD4200-1AC

Lainnya dari Siemens

No image

Siemens

WATER TRAP D TO DIN 16282 120 CEL/100 BAR

M56340-A0063

No image

Siemens

PRESSURE IMPACT REDUCER STAINLESS STEEL

M56340-A0059

No image

Siemens

WATER TRAP B TO DIN 16282 120 CEL/100 BAR

M56340-A0061

No image

Siemens

INSTRUMENT BRACKET

M56340-A0046

No image

Siemens

INSTRUMENT BRACKET

M56340-A0053

No image

Siemens

PRESSURE IMPACT REDUCER BRASS

M56340-A0054

No image

Siemens

INSTRUMENT BRACKET

M56340-A0047

No image

Siemens

INSTRUMENT BRACKET

M56340-A0079