minimum load [%]10
fastening methodscrew and snap-on mounting
mounting positionWith vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° tiltable to the front and back
product brand nameSIRIUS
degree of pollution3, acc. to IEC 60947-4-2
product designationSoft starter
wire length maximum300
derating temperature40
size of engine control deviceS00
control supply voltage 1 at DC110 ... 230
insulation voltage rated value600
operating frequency rated value50 ... 60
display version for fault signalred
product component motor brake outputNo
reference code according to EN 61346-2Q
control supply voltage 1 at AC at 50 Hz110 ... 230
control supply voltage 1 at AC at 60 Hz110 ... 230
— at standard circuit at 40 °C rated value7.5
— at standard circuit at 50 °C rated value10
number of poles for main current circuit3
blocking voltage of the thyristor maximum1 200
continuous operating current [% of Ie] at 40 °C115
number of CO contacts for auxiliary contacts0
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts1
type of voltage of the control supply voltageAC/DC
control supply voltage frequency 1 rated value50
control supply voltage frequency 2 rated value60
installation altitude at height above sea level5 000
operating voltage at standard circuit rated value200 ... 480
contact rating of auxiliary contacts according to ULB300 / R300
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
relative negative tolerance of the operating frequency-10
relative positive tolerance of the operating frequency10
protection class IP on the front according to IEC 60529IP20
relative negative tolerance of the control supply voltage at DC-20
relative positive tolerance of the control supply voltage at DC20
relative negative tolerance of the control supply voltage frequency-10
relative positive tolerance of the control supply voltage frequency10
power loss [W] at operational current at 40 °C during operation typical4
relative negative tolerance of the control supply voltage at AC at 50 Hz-15
relative negative tolerance of the control supply voltage at AC at 60 Hz-15
relative negative tolerance of the operating voltage at standard circuit-15
relative positive tolerance of the control supply voltage at AC at 50 Hz10
relative positive tolerance of the control supply voltage at AC at 60 Hz10
relative positive tolerance of the operating voltage at standard circuit10
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750G
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value3