JRBSupplier
HomeProductsBrandsAboutContact

Company

  • About
  • Contact

Products

  • Products
  • Categories
  • Brands

Quick Links

  • Home
  • Blog

Contact

  • +6281316865740
  • info@jrbsupplier.com
  • Perum. Metro Cendana, Cilegon, Banten

© 2026 JRB Supplier. All rights reserved.

Products

22829 products

Filters

Categories

All Categories
Adhesive Dispensing Systems(104)
Business equipment(6)
Cable and wire entry systems(2)
Connectors(42)
Contractor(5)
Drive technology(0)
Electric and pneumatic sensors(38)
Gate operators, pumps and ventilators(89)
Hand tools(0)
Homeowner(73)
Industrial Coating Systems(118)
Industrial socket/plug applications(24)
Lamps(29)
List of configurators(0)
Meter panels(9)
Nordson EFD(110)
Nordson ELECTRONICS SOLUTIONS(64)
Nordson MEASUREMENT AND CONTROL(34)
Nordson TEST and INSPECTION(62)
Pluggable building installation systems(4)
Polymer Processing Systems(67)
Renewable energy(1)
Signal processing controls(26)
Spare parts for fittings(40)
Telecommunication equipment/office devices(9)
Tools (Press, cut and isolate)(0)
Valves/taps/controls(14)
Vehicle Service(564)
Cables(81)
Cable carrying systems(8)
Installation ducts for wall and ceiling(6)
Installation material for cables and tubes(3)
Cabinet enclosures(1531)
Terminal blocks(272)
Domestic switching devices(3714)
Energy distribution systems(1104)
Low-voltage industrial components(2613)
Relays(290)
Circuit breakers and fuses(6800)
Earthing, lightning and surge protection(233)
Distribution boards(1187)
Programmable logic controllers PLC(640)
Sensors(327)
Light control(2)
Installation bus systems(807)
Antenna and satellite technique(10)
Optical and acoustic signalling equipment(59)
Communication technique(151)
Data and telecommunication(258)
Consumer electronics(28)
Residential heating(45)
Measuring instruments and tester(86)
Meters(121)
Installation, isolation and connection material(22)
Connection material (electrotechnical)(39)
Fasteners(109)
Batteries, chargers and power cords(45)
Alarm installations, emergency call and signalling(12)
Auxiliary material(22)
Devices for distribution board-/surface mounting(586)
Stats, switches and controllers(84)

Specifications

safety transformer by Siemens

Siemens

safety transformer

4AC3740-1

safety transformer by Siemens

Siemens

safety transformer

4AC3763-0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-4TN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-5AN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-5AN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2342-5AT10-0FA0

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2342-5AV00-0EA0

D-Fuse DII 20A gG 500V a.c./440 SENTRON fuse-link DIAZED size DII In 20A gG Un 500V a.c./440V d.c. by Siemens

Siemens

D-Fuse DII 20A gG 500V a.c./440 SENTRON fuse-link DIAZED size DII In 20A gG Un 500V a.c./440V d.c.

5SB2711

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-4TN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-4TN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2642-4TT10-0FA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-5AN00-0EA0

plug connector type 1 N-PE requirement class B by Siemens

Siemens

plug connector type 1 N-PE requirement class B

5SD7418-0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.63; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.63; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2

4AM3242-4TN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.05 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.09; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP54; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.05 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.09; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP54; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2

4AM3242-4TN00-0ED0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.27; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.27; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1

4AM3242-4TT10-0FA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 0.63 /1.8; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 0.9-1.57; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 0.63 /1.8; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 0.9-1.57; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2042-8BC40-0HA0

DIAZED screw cap DIII 63 A 500 V AC/DC ceramic by Siemens

Siemens

DIAZED screw cap DIII 63 A 500 V AC/DC ceramic

5SH113

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 1.44-2.50; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 1.44-2.50; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2142-8BC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 1.4-2.5; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1 /3.5; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 1.4-2.5; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2142-8CC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.0; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.0; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2542-8BC40-0HA0

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.02; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 1.6 /6.9; Upri(V): Y500-440-380+/-20/D289- 254-220+/-11; Usec(V): Y 400 / D 230; Isec(A): 2.3-4.02; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2542-8CC40-0HA0

D adapter screw DII/E27 by Siemens

Siemens

D adapter screw DII/E27

5SH313

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 2.5 /11; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 3.6-6.26; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 3; Pn/Pn(S6)(kVA): 2.5 /11; Upri(V): Y500-400/D289-230; Usec(V): Y 400 / D 230; Isec(A): 3.6-6.26; F(Hz): 50...60; vector group/shielding winding: IIIIII0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AP2742-8BC40-0HA0

......