fire behaviorflame-retardant according to IEC 60332-1-2
cable designation02Y(ST)C 1x2x0.65/2.56-150LI LIY-Z Y 2x1x1.5 VI
weight per length140 kg/km
suitability for useTrailing-type, hybrid cable used for supplying data and power to ET 200pro
design of the shieldOverlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires
security informationSiemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)
tensile load / maximum450 N
number of bending cycles1000000; For use in cable carriers, for 1 million bending cycles with a bending radius of 125 mm and an acceleration of 2.5 m/s²
UL/ETL style / 600 V RatingYes
operating voltage / maximum80 V
number of electrical cores4
UL/ETL listing / 300 V RatingYes; c(ETL)us 3047254 CMG FT4 75°C
operating voltage / RMS value300 V
capacity per length / at 1 kHz30 pF/m
insulation resistance coefficient20 GΩ·m
loop resistance per length / maximum138 Ω/km
shield resistance per length / maximum10 Ω/km
continuous current / of the power lines7.5 A
radiological resistance / to UV radiationnot resistant
conductor cross section / of the power line1.5 mm²
type of electrical connection / FastConnectNo
class of burning behaviour / according to EN 13501-6Eca
symmetrical tolerance of the outer diameter / of cable sheath0.5 mm