ProductsLow-voltage industrial componentsDC-power supplypower supply; phases: 1; Pn(kW): 0.024; Upri(V): 400(415); Usec(V DC): 24; Isec(A DC): 1/1.2 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6
Active

power supply; phases: 1; Pn(kW): 0.024; Upri(V): 400(415); Usec(V DC): 24; Isec(A DC): 1/1.2 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6

Part Number: 4AV2106-2EB00-0A

Brand

Siemens
SiemensVisit Website

Category

DC-power supply

WhatsApp Inquiry

Siemens 4AV2106-2EB00-0A. power supply; phases: 1; Pn(kW): 0.024; Upri(V): 400(415); Usec(V DC): 24; Isec(A DC): 1/1.2 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6, EN 61131-2 >safety transformer<.

Specifications

Dimensions

Width45 mm
Height136 mm
Depth111 mm

Other

vector groupIi0
fastening methodDIN rail
product brand nameSIDAC
protection class IPIP00
certificate of suitabilityCE / cRUus
phase number of the inputs1
number of shielding windings0
type of current of the inputsAC
ambient temperature rated value60
construction form of the iron coreEI 66-88/18
operating resource protection classI
thermal class according to IEC 60085B
type of electrical connection at input for main current circuitscrew-type terminals / tab terminals
type of electrical connection at output for main current circuitscrew-type terminals / tab terminals
output voltage of the measurement signal at analog output at DC maximum28.8
output voltage of the measurement signal at analog output at DC minimum20.4

Downloads

4AV2106-2EB00-0A_datasheet.pdf

Frequently Asked Questions

You May Also Like

power supply; phases: 1; Pn(kW): 0.024; Upri(V): 230-115; Usec(V DC): 24; Isec(A DC): 1/1.2 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 by Siemens

Siemens

power supply; phases: 1; Pn(kW): 0.024; Upri(V): 230-115; Usec(V DC): 24; Isec(A DC): 1/1.2 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6

4AV2102-2EB00-0A

power supply; phases: 1; Pn(kW): 0.06; Upri(V): 400-230+/-15; Usec(V DC): 24; Isec(A DC): 2.5/3 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw connection; mounting: screws / DIN rail; EN 61558-2-6 by Siemens

Siemens

power supply; phases: 1; Pn(kW): 0.06; Upri(V): 400-230+/-15; Usec(V DC): 24; Isec(A DC): 2.5/3 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw connection; mounting: screws / DIN rail; EN 61558-2-6

4AV2000-2EB00-0A

power supply; phases: 1; Pn(kW): 0.06; Upri(V): 400-230(240)-115(120); Usec(V DC): 24; Isec(A DC): 2.5/3 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw connection; mounting: screws / DIN rail; EN 61558-2-6 by Siemens

Siemens

power supply; phases: 1; Pn(kW): 0.06; Upri(V): 400-230(240)-115(120); Usec(V DC): 24; Isec(A DC): 2.5/3 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw connection; mounting: screws / DIN rail; EN 61558-2-6

4AV2001-2EB00-0A

power supply; phases: 1; Pn(kW): 0.12; Upri(V): 400-230+/-15; Usec(V DC): 24; Isec(A DC): 5/6 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 by Siemens

Siemens

power supply; phases: 1; Pn(kW): 0.12; Upri(V): 400-230+/-15; Usec(V DC): 24; Isec(A DC): 5/6 (60/40 CEL); F(Hz): 50...60; vector group/shielding winding: II0 /0; protection class: I; temperature rise/insulation class: 60 /B; W(%): 5; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6

4AV2200-2EB00-0A

No image

ABB

NT/S12.1600 - DC-power supply

GHQ6050056R0002

No image

ABB

NT/S 24.800 - DC-power supply

GHQ6050057R0002

No image

ABB

NTU/S12.2000.1 - DC-power supply

2CDG110070R0011

No image

ABB

CP-D24/2.5 - DC-power supply

2CDG120037R0011

More from Siemens

No image

Siemens

WATER TRAP D TO DIN 16282 120 CEL/100 BAR

M56340-A0063

No image

Siemens

PRESSURE IMPACT REDUCER STAINLESS STEEL

M56340-A0059

No image

Siemens

WATER TRAP B TO DIN 16282 120 CEL/100 BAR

M56340-A0061

No image

Siemens

INSTRUMENT BRACKET

M56340-A0046

No image

Siemens

INSTRUMENT BRACKET

M56340-A0053

No image

Siemens

PRESSURE IMPACT REDUCER BRASS

M56340-A0054

No image

Siemens

INSTRUMENT BRACKET

M56340-A0047

No image

Siemens

INSTRUMENT BRACKET

M56340-A0079