JRBSupplier
HomeProductsBrandsAboutContact

Company

  • About
  • Contact

Products

  • Products
  • Categories
  • Brands

Quick Links

  • Home
  • Blog

Contact

  • +6285121062779
  • info@jrbsupplier.com
  • Cilegon, Banten

© 2026 JRB Supplier. All rights reserved.

ProductsRelaysSpeed-/standstill monitoring relay!!! product phase-out !!! the preferred successor is 3UG5851-1AA40 digital monitoring relay speed monitoring for IO-Link from 0.1 to 2200 r/min overshoot and undershoot ON-delay time tripping delay time hysteresis 0.1 to 99 r/min 1 changeover contact
Active

!!! product phase-out !!! the preferred successor is 3UG5851-1AA40 digital monitoring relay speed monitoring for IO-Link from 0.1 to 2200 r/min overshoot and undershoot ON-delay time tripping delay time hysteresis 0.1 to 99 r/min 1 changeover contact

Part Number: 3UG4851-1AA40

Brand

Siemens
SiemensVisit Website

Category

Speed-/standstill monitoring relay

WhatsApp Inquiry

Siemens 3UG4851-1AA40. !!! product phase-out !!! the preferred successor is 3UG5851-1AA40 digital monitoring relay speed monitoring for IO-Link from 0.1 to 2200 r/min overshoot and undershoot ON-delay time tripping delay time hysteresis 0.1 to 99 r/min 1 changeover contact, screw terminal.

Specifications

Mechanical

Net Weight0.163 kg

Dimensions

Width22.5 mm
Height91 mm
Depth102 mm

Other

— upwards0 mm
— forwards0 mm
— backwards0 mm
— downwards0 mm
— at the side0 mm
— at 24 V maximum4 VA
fastening methodscrew and snap-on mounting
product functionRPM monitoring relay
mounting positionany
— delayed switching0
product brand nameSIRIUS
degree of pollution2
product designationSpeed monitoring relay with digital setting
IO-Link transfer rateCOM2 (38,4 kBaud)
design of the displayLCD
— instantaneous contact0
product type designation3UG4
relative repeat accuracy1 %
accuracy of digital display+/- 1 Digit
relative metering precision10 %
Substance Prohibitance (Date)05/01/2012
type of electrical connectionscrew terminal
design of input feedback inputNo
adjustable operating delay time0 ... 99.9 s
operational current at 17 V minimum5 mA
surge voltage resistance rated value4 kV
protocol is supported IO-Link protocolYes
reference code according to IEC 81346-2K
— with degree of pollution 2 rated value300 V
number of CO contacts delayed switching1
number of NC contacts delayed switching0
number of NO contacts delayed switching0
control supply voltage at DC rated value24 ... 24 V
shock resistance according to IEC 60068-2-27sinusoidal half-wave 15g / 11 ms
suitability for use safety-related circuitsNo
tightening torque with screw-type terminals0.8 ... 1.2 N·m
type of voltage of the control supply voltageDC
vibration resistance according to IEC 60068-2-61 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
operating frequency with 3RT2 contactor maximum5 000 1/h
ampacity of the semiconductor output in SIO mode200 mA
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
field-based interference according to IEC 61000-4-310 V/m
mechanical service life (operating cycles) typical10 000 000
Safety Integrity Level (SIL) according to IEC 61508without
type of voltage supply via input/output link masterYes
installation altitude at height above sea level maximum2 000 m
protection class IP on the front according to IEC 60529IP20
continuous current of the DIAZED fuse link of the output relay4 A
electrical endurance (operating cycles) at AC-15 at 230 V typical100 000
thermal current of the switching element with contacts maximum5 A
point-to-point cycle time between master and IO-Link device minimum10 ms
product component removable terminal for auxiliary and control circuitYes

Downloads

3UG4851-1AA40_doc_03UG4851-1AA40_doc_13UG4851-1AA40_doc_23UG4851-1AA40_doc_33UG4851-1AA40_doc_43UG4851-1AA40_doc_53UG4851-1AA40_doc_63UG4851-1AA40_doc_73UG4851-1AA40_doc_83UG4851-1AA40_doc_93UG4851-1AA40_doc_103UG4851-1AA40_doc_113UG4851-1AA40_datasheet.pdf

Frequently Asked Questions

You May Also Like

No image

Siemens

Digital monitoring relay Speed monitoring from 50 to 60 rpm for 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay 1 NO Tripping delay 0.1 s Without hysteresis 1 change-over contact Automatic reset screw terminal

3UG4651-1AA38-0AA8-ZX95

!!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer screw terminal by Siemens

Siemens

!!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer screw terminal

3UG4651-1AW30

!!! product phase-out !!! the preferred successor is 3UG5651-2CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer spring-loaded connection system by Siemens

Siemens

!!! product phase-out !!! the preferred successor is 3UG5651-2CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer spring-loaded connection system

3UG4651-2AA30

!!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer by Siemens

Siemens

!!! product phase-out !!! the preferred successor is 3UG5651-1CW30 digital monitoring relay speed monitoring from 0.1 to 2200 r/min overshoot and undershoot supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without electrical isolation to the measuring circuit ON-delay 1 to 900 s tripping delay 0.1 to 99.9 s hysteresis 0.1 to 99 r/min 1 changeover contact with or without fault buffer

3UG4651-1AA30

FOUR WIRE CONNECTION LEAD TO CONNECT SICAM FCM TO CAPACITIVE LRM VOLTAGE DETECTION SYSTEMS LENGTH 30 CM ONE END CABLE END SLEEVES OTHER END FLAT SOCKET by Siemens

Siemens

FOUR WIRE CONNECTION LEAD TO CONNECT SICAM FCM TO CAPACITIVE LRM VOLTAGE DETECTION SYSTEMS LENGTH 30 CM ONE END CABLE END SLEEVES OTHER END FLAT SOCKET

6MD2322-0AA80-0AB3

DIRECTIONAL SHORT CIRCUIT AND EARTH FAULT DETECTOR VOLTAGE MEASUREMENT VIA CAPACITIVE VOLTAGE DIVIDER EARTH FAULT DETECTOR FOR LOW-POWER CURRENT SENSORS 1 BINARY INPUT 2 BINARY OUTPUTS MEASUREMENT/CALCULATION OF VALUES U by Siemens

Siemens

DIRECTIONAL SHORT CIRCUIT AND EARTH FAULT DETECTOR VOLTAGE MEASUREMENT VIA CAPACITIVE VOLTAGE DIVIDER EARTH FAULT DETECTOR FOR LOW-POWER CURRENT SENSORS 1 BINARY INPUT 2 BINARY OUTPUTS MEASUREMENT/CALCULATION OF VALUES U

6MD2322-1AA00-1AA0

DIRECTIONAL SHORT CIRCUIT AND EARTH FAULT DETECTOR VOLTAGE MEASUREMENT VIA RESISTIVE VOLTAGE DIVIDER by Siemens

Siemens

DIRECTIONAL SHORT CIRCUIT AND EARTH FAULT DETECTOR VOLTAGE MEASUREMENT VIA RESISTIVE VOLTAGE DIVIDER

6MD2321-1AA00-1AA0

LOW-POWER PHASE CURRENT SENSOR CLOSED CORE TYPE ACCORDING TO IEC 61869-10 RATIO: 225 MV@700 A INNER DIAMETER 82 MM ACCURACY CLASS: 0.2 (FCM V 3.30 ONWARDS) by Siemens

Siemens

LOW-POWER PHASE CURRENT SENSOR CLOSED CORE TYPE ACCORDING TO IEC 61869-10 RATIO: 225 MV@700 A INNER DIAMETER 82 MM ACCURACY CLASS: 0.2 (FCM V 3.30 ONWARDS)

6MD2320-0JA00-0BA1

More from Siemens

No image

Siemens

WATER TRAP D TO DIN 16282 120 CEL/100 BAR

M56340-A0063

No image

Siemens

PRESSURE IMPACT REDUCER STAINLESS STEEL

M56340-A0059

No image

Siemens

WATER TRAP B TO DIN 16282 120 CEL/100 BAR

M56340-A0061

No image

Siemens

INSTRUMENT BRACKET

M56340-A0046

No image

Siemens

INSTRUMENT BRACKET

M56340-A0053

No image

Siemens

PRESSURE IMPACT REDUCER BRASS

M56340-A0054

No image

Siemens

INSTRUMENT BRACKET

M56340-A0047

No image

Siemens

INSTRUMENT BRACKET

M56340-A0079