One-phase control transformer

JRB Supplier is a trusted industrial supplier of One-phase control transformer in Indonesia. Browse the catalog below and request a quote for the part you need.

Products in One-phase control transformer

75 products

Product Categories
Low-voltage industrial components
transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2642-5AT10-0FA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-4TN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-5AN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-5AN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.05 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.09; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP54; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.05 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.09; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP54; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2

4AM3242-4TN00-0ED0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.17; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2642-4TT10-0FA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: DIN rail; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-4TN00-0EB0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-5AN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-4TN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.04 /0; Upri(V): 400+/-5%; Usec(V): 24; Isec(A): 1.67; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2642-5AN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 110; Isec(A): 0.57; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 110; Isec(A): 0.57; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1

4AM3242-4TJ10-0FA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.63; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 2.63; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-2

4AM3242-4TN00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.27; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.063 /0.19; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.27; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws / DIN rail; EN 61558-2-1

4AM3242-4TT10-0FA0

isolation transformer; phases: 1; Pn(kVA): 0.04; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.952; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

isolation transformer; phases: 1; Pn(kVA): 0.04; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.952; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2642-5AV00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-4TN00-0EA0

safety transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: cage-clamp; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer< by Siemens

Siemens

safety transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 230+/-5%; Usec(V): 24; Isec(A): 1.04; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: cage-clamp; mounting: screws; EN 61558-2-6 >UL/CSA-recognized< >safety transformer<

4AM2342-4TN00-0EA1

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 230+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2342-4TT10-0FA0

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 230+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-4 >UL/CSA-recognized< >isolation transformer< by Siemens

Siemens

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 230+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-4 >UL/CSA-recognized< >isolation transformer<

4AM2342-4TV00-0EA0

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

transformer SITAS; phases: 1; Pn/Pn(S6)(kVA): 0.025 /0; Upri(V): 400+/-5%; Usec(V): 230; Isec(A): 0.11; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2342-5AT10-0FA0

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1 by Siemens

Siemens

isolation transformer; phases: 1; Pn(kVA): 0.025; Upri(V): 400+/-5%; Usec(V): 42; Isec(A): 0.595; F(Hz): 50...60; vector group/shielding winding: II0 /0; temperature rise/insulation class: 40 /B; IP00; connection: screw/flat-type connection; mounting: screws; EN 61558-2-1

4AM2342-5AV00-0EA0

No image

ABB

TM-C 1600/12-24 - One-phase control transformer

2CSM292863R0801

No image

ABB

TM-S 250/24-48 P - One-phase control transformer

2CSM204683R0801

No image

ABB

TM-S 630/24-48 P - One-phase control transformer

2CSM204603R0801

No image

ABB

TM-S 320/24-48 P - One-phase control transformer

2CSM204673R0801